Sensors and DAQAccuracy vs Resolution: Precision & Error Specs in DAQ
Accuracy measures closeness to a true value across bias and random scatter, whereas resolution is the smallest step a DMM, sensor, or ADC can detect.
Technical articles and guides tagged with #daq.
Sensors and DAQAccuracy measures closeness to a true value across bias and random scatter, whereas resolution is the smallest step a DMM, sensor, or ADC can detect.
Sensors and DAQCompare inductive eddy-current and capacitive electric-field sensors by target metal or dielectric permittivity, sensing footprint, moisture drift, and touch.
Sensors and DAQGround low-frequency analog DAQ cable shields at one end to stop ground loops, and bond RF or VFD motor shields at both ends with 360-degree clamps.
Sensors and DAQAn analog low-pass before the ADC stops out-of-band energy from folding into the samples. Match cutoff, roll-off, and delay to the sample rate.
Sensors and DAQUnder ASTM E251-20a, strain gage accuracy cannot exceed gage factor accuracy, while additive thermal output and leadwire resistance require compensation.
Sensors and DAQLoad cells resolve applied load using only rated output in mV/V, excitation voltage, and rated capacity without needing internal bridge Gauge Factor.
Sensors and DAQCalculate gauge-factor scaling from calibration on Poisson ratio 0.285, instrument and temperature rescaling, and transverse sensitivity corrections.
Sensors and DAQCompare dynamic versus static strain gauge measurement across monotonic microstrain range, cyclic S-N fatigue life, thermal output zero drift, and excitation limits.
Partition an automated test bench across a precision DMM, digital oscilloscope, and modular DAQ using IEEE 1241 ENOB, NPLC power-line rejection, CAT II isolation, and sensor bandwidth.
Size strain gauge amplifier gain, excitation power density, 6-wire Kelvin remote sensing, DC vs AC carrier demodulation, anti-aliasing filters, and shunt calibration.
Sensors and DAQMatch a thermocouple, Pt100, or NTC to the DAQ using IEC 60751 ranges, ASTM E230-87 tolerances, and the excitation current that heats the sensor.
Sensors and DAQCheck leadwire resistance symmetry, terminal roles, bridge offset nulling, and shunt calibration placement on a three-wire quarter-bridge strain gauge channel before logging.
Sensors and DAQCompare single-channel and scanned readings, then vary timing, order, and voltage steps to test suspected DAQ ghosting with a blank observation record.
Sensors and DAQLocate the thermocouple-to-copper transition, check the selected CJC source, and record terminal temperatures before diagnosing a drifting DAQ channel.
Sensors and DAQCopy the wire count and the DAQ input type before you pick a shunt or a supply. Leave ohms, supply voltage, and loop resistance blank until the manual states them.
Sensors and DAQHow to wire floating sources to differential DAQ inputs: choose jumper, single, or dual bias resistors, check common-mode limits, and ground cable shields.
Sensors and DAQSet a DAQ sample rate above the 2x Nyquist floor, from 10x for waveform shape to 20x for control, check multiplexed vs. simultaneous limits, and size storage.
Test and MeasurementDecide between a triggered oscilloscope capture and a continuous DAQ log using the event, the file you must keep, and the input the circuit actually presents.